Marine electrical systems · Distribution & power

Boat electrical systems
in Raiatea.

Discharging batteries, a faulty charger, a tripping circuit or unstable shore power: Naval LEO-SOLUTIONS diagnoses the installation in Raiatea and defines suitable work.

01

Circuit and distribution diagnostics

We start by reviewing power sources, switchboards and affected loads. Targeted measurements help locate the fault and establish a clear scope of work.

  • Fault finding on 12/24 V DC and 230 V AC circuits.
  • Measure relevant voltages, voltage drops and loads.
  • Check connections, switchboards, protective devices and distribution circuits.
  • Repair or replace components included in the quotation.
02

Batteries, charging and power conversion

The battery bank, onboard loads and charging sources, including the boat’s solar system, operate as one system. Any upgrade needs to consider chargers, alternators, controllers, inverters, protection and cable sizing.

  • Diagnose battery banks and charging circuits.
  • Assess, install or replace chargers and inverters.
  • Check compatibility when changing battery chemistry.
  • Adapt wiring, protection and labelling to the agreed work.
03

Reliability checks and upgrades

Before a passage, refit or new equipment installation, Naval LEO-SOLUTIONS can perform targeted checks and size the required changes. Surveys or diagrams are defined within the quoted scope.

  • Preventive inspection and summary of findings.
  • Load assessment and sizing of planned upgrades.
  • Circuit identification and documentation of modifications.
  • Functional tests after the work.

Common questions

Answers to common questions.

My battery discharges quickly. Is the battery necessarily faulty?

No. Onboard loads, charging sources and poor connections can also affect discharge. We assess the battery bank within the complete system to identify suitable work.

Can I change battery chemistry without modifying the installation?

It depends on the system. Chargers, charging sources, circuit protection and wiring must be assessed to define any adaptations before replacement.